DUAL LASER IR THERMOMETER (Not suitable for human use) - IC-Fluke-572-2
Order Me In, Once ordered this item will likely dispatch before the 14th of November 2025, call 1300 737 871 (NZ 0800 737 871) to confirm.
$2,315.50 AUD Inc. GST




Note: This particular thermometer isnt suitable for human use, please see the following options for this application; https://www.instrumentchoice.com.au/instrument-choice/environment-meters/ir-thermometers/forehead-thermometers
With a straight-forward user interface and soft-key menus, the Fluke 572-2 makes even complex measurements easy. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button.
Features:
Measures -30 C to 900 C (-22 F to 1652 F)
Has 60:1 distance to spot ratio with dual laser sighting for fast, accurate targeting
Multi-language interface (user select)
Current Temperature plus MAX, MIN, DIF, AVG temperature displays
Compatible with standard mini-connector K-type thermocouples, including ones you already own and have installed
Adjustable emissivity and predefined emissivity table
Infrared and thermocouple temperature on back-lit display
Last reading Hold (20 seconds)
High and low temperature alarm
Data storage and review (99 data sets)
Tripod mount
12 or 24 hour clock
USB 2.0 computer interface cable
FlukeView Forms documenting software
Warranty:
2 Years Manufacturer Warranty + Additional 1 Year Instrument Choice Warranty
Specifications
Infrared Measurements | |
Infrared temperature range | -30 C to 900 C (-22 F to 1652 F) |
IR accuracy (calibration geometry with ambient temperature 23 C ? 2 C) |
>= 0C: +- 1C or +- 1 % of the reading, whichever is greater >= -10C to <0 C: +-2C <-10C: +-3 C >= 32F: +- 2F or +- 1% of the reading, whichever is greater >= 14 F to <32 F: +-4 F < 14 F: +-6 F |
IR repeatability | +- 0.5 % of reading or +-0.5 C (+-1 F), whichever is greater |
Display resolution | 0.1 C / 0.1 F |
Distance: Spot | 60:1 (calculated at 90 % energy) |
Minimum spot size | 19 mm |
Laser sighting | Offset dual laser, output <1 mW |
Spectral response | 8 um to 14 um |
Response time (95 %) | <500 ms |
Emissivity | Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials |
Contact Measurements | |
K-type thermocouple input accuracy (with ambient temperature 23 ?C ? 2 ?C) |
<- 40 C: +-(1 C + 0.2 /1 C) |
>= -40 C: +-1 % or 1 C, whichever is greater | |
<- 40 F: +-(2 F + 0.2 /1 F) | |
>= -40 F: +-1 % or 2 F, whichever is greater | |
K-type thermocouple | 0.1 C/0.1 F |
K-type thermocouple repeatability | +- 0.5 % of reading or +- 0.5 C (+- 1 F), whichever is greater |
Measurement Options | |
Hi/Low alarms | Audible and two-color visual |
Min/Max/Avg/Dif | Yes |
Switchable celsius and fahrenheit | Yes |
Backlight | Two levels, normal and extra bright for darker environments |
Probe input | K-type thermocouple simultaneous display of probe and IR temperature |
Trigger lock | Yes |
Data storage | 99 points |
Display | Dot matrix 98 x 96 pixels with function menus |
Communication | USB 2.0 |
K-Type Thermocouple Specifications | |
Measurement range (bead probe) | -40 C to 260 C (-40 F to 500 F) |
Accuracy | +- 1.1 C (+- 2.0 F) from 0 C to 260 C (32 F to 500 F). Typically within 1.1 C (2.0 F) from -40 C to 0 C (-40 F to 32 F) |
Cable length | 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination |
General Specifications | |
Safety and compliance | IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009 |
Operating temperature | 0 C to 50 C (32 F to 122 F) |
Storage temperature | -20 C to 60 C (-4 F to 140 F) |
Relative humidity | 10 % to 90 % RH non-condensing up to 30 C (86 F) |
Operating altitude | 2000 meters above mean sea level |
Weight | 0.322 kg (0.7099 lb) |
Power | 2 AA batteries |
Battery life | 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle (thermometer continuously on) |
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au