4 Channel Thermocouple Data Logger
Product code: UX120-014M
|
The HOBO UX120 Thermocouple Logger is a four-channel LCD data logger for measuring and recording temperature in a broad range of monitoring applications. The logger makes it easy and convenient to record temperatures over a broad range (-260 to 1820 C) and can accept up to four J, K, T, E, R, S, B, or N type probes. In addition to accepting four thermocouple probes, the logger features an internal temperature sensor for logging ambient temperatures, further extending the range of application possibilities. Features: - Easy-to view LCD display confirms logger operation and battery status- Near real-time readout of current temperatures as well as minimum, maximum, average and standard deviation statistics - Large memory capacity capable of storing 1.9 million measurements - On-screen alarms notify you if temperatures exceed high or low thresholds - Start, stop, and restart pushbuttons - User upgradeable firmware Environment: The UX120-014M Data Logger is for use in Indoor environments
|
|
What does the UX120-014M measure:
- Temperature
IMPORTANT: Requires Hoboware Free or Hoboware-Pro software for proper operation
Specifications:
|
Thermocouple |
|||
|
Type |
Range |
Accuracy |
Resolution |
|
J |
-210 to 760 C (-346 to 1,400 F) |
+/- 0.6 C (+/- 1.08 F) thermocouple probe accuracy |
0.03 C (0.06 F) |
|
K |
-260 to 1,370 C (-436 to 2,498 F) |
+/- 0.7 C (+/- 1.26 F) thermocouple probe accuracy |
0.04 C (0.07 F) |
|
T |
-260 to 400 C (-436 to 752 F) |
+/- 0.6 C (+/- 1.08 F) thermocouple probe accuracy |
0.02 C (0.03 F) |
|
E
|
-260 to 950 C (-436 to 1,742 F) |
+/- 0.6 C (+/- 1.08 F) thermocouple probe accuracy |
0.03 C at (0.05 F) |
|
R |
-50 to 1,550 C (-58 to 2,822 F) |
+/- 2.2 C (+/- 3.96 F) thermocouple probe accuracy |
0.08 C (0.15 F) |
|
S |
-50 to 1,720 C (-58 to 3,128 F) |
+/- 2.2 C (+/- 3.96 F) thermocouple probe accuracy |
0.08 C (0.15 F) |
|
B |
550 to 1,820 C (1,022 to 3,308 F) |
+/- 2.5 C (+/- 4.5 F) thermocouple probe accuracy |
0.1 C (0.18F) |
|
N |
-260 to 1,300 C (-436 to 2,372 F) |
+/- 1.0 C (+/- 1.8F) thermocouple probe accuracy |
0.06 C (0.11 F) |
|
Internal 10K Thermistor (Temperature): |
||
|
Range Logging |
-20 to 70 C (-4 to 158 F) |
|
|
Accuracy |
+/- 0.21 C from 0 to 50 C (0.38 F from 32 to 122 F), see Plot A |
|
|
Resolution |
0.024 C at 25 C (0.04 F at 77 F); see Plot A |
|
|
Drift |
<0.1 C (0.18 F) per year |
|
|
Logger Operating Range |
Logging: -20 to 70 C (-4 to 158 F); 0 to 95% RH (non-condensing); logger accuracy from 0 to 50 C (32 to 122 F) Launch/Readout: 0 to 50 C (32 to 122 F) per USB specification |
|
Logging Rate |
1 second to 18 hours, 12 minutes, 15 seconds |
|
Logging Modes |
Normal, Burst or Statistics |
|
Memory Modes |
Wrap when full or stop when full |
|
Time Accuracy |
1 minute per month at 25 C (77 F), see Plot B |
|
Start Modes |
Immediately, Push Button, Date & Time or Next Interval |
|
Stop Modes |
When Memory Full, Push Button, or Date & Time |
|
Restart Mode |
Push Button |
|
Memory |
4 MB (1.9 million measurements, maximum) |
|
Download Type |
USB 2.0 interface |
|
Full Memory Download Time |
Approximately 1.5 minutes |
|
LCD |
LCD is visible from: 0 to 50 C (32 to 122 F); the LCD may react slowly or go blank in temperatures outside this range. |
|
IP Rating |
IP50 |
Battery Type: Two AAA 1.5V alkaline batteries, user replaceable
10.8 x 5.41 x 2.54 cm
Weight: 30 g
Warranty
- 1 Year Manufacturer Warranty + Additional 1 Year Instrument Choice Warranty
| File | Type | Size | Created At |
|---|---|---|---|
| HOBO UX120 Series Data Sheet | 1.29 MB | 27/1/2021, 2:23 PM | |
| UX120-014M User's Manual | 769.78 KB | 27/1/2021, 2:23 PM |
Delivery Details
FREE Startrack Premium in Australia
|
|---|
Free Delivery in Australia for orders over $100 Overnight delivery to most capital cities and surrounding areas, click here for availability (2 to 5 day delivery outside these locations.)
- Delivered only on business days at your location, delivery unavailable on weekends and public holidays
- Shipped from Instrument Choice on South Australian working days
This service does not deliver to Post Office Boxes
Free Delivery in Australia for orders over $100
|
For alternate delivery options and international shipping, click here.
Why Instrument Choice?

#1. SUPER-RESPONSIVE CUSTOMER SERVICE

#2. SPECIAL ADVICE FROM SCIENTISTS

#3. Easy Shopping

#4. Free Express Shipping
Why pay for shipping when Instrument Choice has negotiated such amazing freight rates for Australia and New Zealand? Overnight shipping is available to capital cities for 93% of stocked items, the rest still travel by express road to get to you quickly.
Get details about our super-fast and secure shipping options here