USB Relative Humidity-Temperature Logger, Graphic LCD with Calibration Certificate - IC-EL-GFX-2 CAL-T/H
ORDER ME IN
The EL-GFX-2 standalone USB data logger measures and stores over 250,000 temperature and humidity readings over a -30 to +80C (-22 to 176F) and 0 to 100%RH range at a resolution of 0.1C and 0.1%RH. Calibrated at 20 C, 40 C, 35% RH at 20 C and 75% RH at 20 C.




Features:
* This specifies the overall error in the logged readings, for relative humidity measurements between 20 and 80%RH.
** This specifies the overall error in the calculated dew point for relative humidity measurements between 40 and 100%RH at 25C.
*** At temperatures below -5C the LCD will exhibit slower response times. The LCD will be disabled at temperatures under -20C and above 70C.
At 25C and 10 minute logging rate, with no alarm LEDs or sounder and minimal LCD use.
Multimedia
* -30 to +80C and 0 to 100% RH measurement ranges
* Logging rates between 10 seconds and 1 hour
* Immediate, delayed, push-button or temperature/RH
triggered start mode
* Graphic LCD shows real-time readings, graph and
current status
* Stores over 250,000 readings
* Tested at 20 C, 40 C, 35% RH at 20 C and 75%
RH at 20 C.
The data logger's robust design provides IP-67 waterproof protection and the two replaceable 1/2 AA batteries typically allow logging for up to one
year.
As a recently introduced product, stock of this product may be limited. If your requirement is urgent please contact Lascar directly for up to date lead-time information before ordering online.
As a recently introduced product, stock of this product may be limited. If your requirement is urgent please contact Lascar directly for up to date lead-time information before ordering online.
Specifications
Relative Humidity |
Measurement Range |
0 to 100 %RH |
Internal Resolution |
+-0.1 %RH |
|
Accuracy (overall error) |
+-3.0* to +-5.0 %RH |
|
Repeatability |
0.5 %RH |
|
Long term stability |
0.5 %RH/Year |
|
Temperature |
Measurement Range |
-30 - +80C / -22 - +176F |
Internal Resolution |
0.1C / 0.1F |
|
Accuracy (overall error) |
+-0.5 to +-2.0C +-1.0 to +-4.0F |
|
Repeatability |
+-0.1C / +-0.2F |
|
Logging Rate |
10s, every 12hrs |
|
Dew Point Accuracy (overall error) |
+-1.1C / +-2.0F |
|
Operating Temperature Range |
3 to +80 C / -22 - +176F |
Power:
2 x 1/2 AA 3.6V Lithium
Battery Life 1 year
* This specifies the overall error in the logged readings, for relative humidity measurements between 20 and 80%RH.
** This specifies the overall error in the calculated dew point for relative humidity measurements between 40 and 100%RH at 25C.
*** At temperatures below -5C the LCD will exhibit slower response times. The LCD will be disabled at temperatures under -20C and above 70C.
At 25C and 10 minute logging rate, with no alarm LEDs or sounder and minimal LCD use.
Multimedia
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au