The easy to use testo 480 is a high precision digital temperature and humidity meter which allows you to measure, analyze, and log all relevant ventilation and air conditioning parameters with only one device.
This high precision digital temperature and humidity meter provides independent experts, consultants, technical service providers, and service technicians
in the field of ventilation and AC with an efficient means of carrying out all their measurements, i.e. norm-compliant setting and adjustment
of air conditioning and ventilation systems in offices, residential and industrial buildings - with only one device.
It is also designed to check quality parameters in production and processing quickly and reliably. The intelligent concept behind the testo 480 digital
temperature and humidity meter
The testo 480 has a built-in high precision pressure difference sensor for pitot static tube measurements and filter / clean room monitoring. There is
also a wide range of high quality optional sensors for carrying out the following measurements:
- Air flow and volume flow (also fume cupboard measurements)
- Temperature
- Humidity
- Pressure (difference and absolute pressure)
- CO2
- Illumination intensity
- PMV / PPD
- Heat radiation
- Degree of turbulence
- WBGT Index
State of the art technology for VAC technicians and experts
The testo 480 was designed to make your work more efficient, and your life easier. This high quality, easy to use digital temperature and humidity meter
can be used to measure all relevant ventilation and AC parameters, and to carry out long term measurements. The mammoth memory can save up to 60 million
readings, and a set of integrated programs guide you through the following measurements step by step.
- VAC measurements in compliance with EN 12599
- Degree of turbulence measurements in compliance with EN 12599
- PMV / PPD measurement in compliance with ISO 7730
- WBGT measurement in compliance with ISO 7243
Specifications
Temperature - Pt100:
- Measuring range: -148 to +752 F / -100 to +400 C
- Resolution: 0.01 F / 0.01 C
Temperature - Type K TC:
- Measuring range: -328.0 to 2498.0 F / -200 to +1370 C
- Accuracy: +/- (0.5 F to 0.1 % of mv) / +/- (0.3 C to 0.1 % of mv)
- Resolution: 0.1 F / 0.1 C
Humidity - Capacitive:
- Measuring range: 0 to 100 %rH
- Resolution: 0.1 %rH
Velocity - Vane anemometer:
- Measuring range: 118.1 to +9843 fpm (vane anemometer 16 mm) / 0.6 to +50 m/s (vane anemometer 16 mm)/19.7 to +2953 fpm (vane anemometer 100 mm) / 0.1
to +15 m/s (vane anemometer 100 mm)
- Resolution: 0.1 fpm (vane anemometer 16 mm) / 0.1 m/s (vane anemometer 16 mm)/0.01 fpm (vane anemometer 100 mm) / 0.01 m/s (vane anemometer 100 mm)
Velocity - Hot wire anemometer:
- Measuring range: 0 to +3937 fpm / 0 to +20 m/s
- Resolution: 1.97 fpm / 0.01 m/s
Ambient Carbon dioxide:
- Measuring range: 0 to 10000 ppm Carbon dioxide
- Resolution: 1 ppm Carbon dioxide
Comfort level measurement:
- Measuring range: 0 to +984 fpm / 0 to +5 m/s
- Resolution: 0.01 fpm / 0.01 m/s
Differential pressure (internal sensor) - Piezoresistive:
- Measuring range: -40 to +40 InH2O / -100 to +100 hPa
- Accuracy: +/- (0.0 InH2O + 1 % of mv) (0 to +10 InH?O) / +/- (0.3 Pa + 1 % of mv) (0 to +25 hPa)/ +/- (0.0 InH2O + 1.5 % of mv) (+10.000 to +40 InH2O)
/ +/- (0.1 hPa + 1.5 % of mv) (+25.001 to +100 hPa)
- Resolution: 0.000 InH2O / 0.001 hPa
Light:
- Measuring range: 0 to 100000 Lux
- Resolution: 1 Lux
Absolute Pressure (internal sensor and external probe):
- Measuring range: 280 to 440 InH?O / 700 to 1100 hPa
- Accuracy: +/- 1 InH2O / +/- 3 hPa
- Resolution: 0.1 InH2O / 0.1 hPa