With its ability to perform both basic and more complex combustion analysis, maintenance, safety checks, and boiler efficiency confirmations, the fully featured testo 310 residential combustion analyzer is ready to provide accurate analysis.
The stainless steel probe and cone-stop are perfect for residential and boiler efficiency applications. Simple top-of-display icons show you the current
measurement functions. After only 30 seconds, the testo 310 is ready to test.
With five different fuels to select from (natural gas, propane, fuel oil 2, biomass 5%, and wood 20%), it provides the flexibility you need for all your
residential combustion analysis applications.
Measures:
- O2, CO (with built-in NOx filter), CO2
- Undiluted CO (CO air free)
- Ambient CO
- Draft & pressure
- Temperature (flue & ambient)
- Combustion / flue gas efficiency & excess air
Features:
- Wireless printer with integrated magnets for professional jobsite documentation
- All the measurements you need, including draft and pressure
- Fast 30-second startup so you can get testing quickly
- Integrated kink-resistant probe hose eliminates leaks
Specifications
(ambient temperature)
Temperature - Type K TC:
- Measuring range: -4 to 212 F / -20 to +100 C
- Accuracy: +/- 2 F / +/- 1 C
- Resolution: 0.1 F / 0.1 C
- Reaction time: < 50 sec
Temperature - Type J TC:
- Measuring range: 32 to 752 F / 0 to +400 C
- Accuracy: +/- 1.8 F (32 to 212 F) / +/- 1 C (0 to +100 C)/+/- 1.5 % of mv (> 212 F) / +/- 1.5 % of mv (> 100 C)
- Resolution: 0.1 F / 0.1 C
- Reaction time: < 50 sec
Specifications
(Flue Gas)
Flue gas (Oxygen):
- Measuring range: 0 to 21 Vol.%
- Accuracy: +/- 0.2 Vol.%
- Resolution: 0.1 Vol.%
- Reaction time: 30 sec
Flue Gas Draft:
- Measuring range: -8 to +8 InHO / -20 to +20 hPa/ ?0.01 InH2O (-1 to +1 InH2O) / +/- 0.03 hPa (-3 to +3 hPa)
- Accuracy: +/- 1.5 % of mv (Remaining Range)
- Resolution: 0.00 InH?O / 0.01 hPa
Efficiency (calculated):
- Measuring range: 0 to 120 %
- Resolution: 0.1 %
Flue Gas loss (calculated):
- Measuring range: 0 to 99.0 %
- Resolution: 0.1 %
Flue Gas Carbon dioxide calculation (calculated from Oxygen):
- Measuring range: 0 to CO max (Display range)
- Accuracy: +/- 0.2 Vol.%
- Resolution: 0.1 Vol.%
- Reaction time: < 40 sec
Flue gas CO (without Hydrogen-compensation):
- Measuring range: 0 to 4000 ppm
- Accuracy: +/- 20 ppm (0 to 400 ppm)/+/- 5 % of mv (401 to 2000 ppm)/+/- 10 % of mv (2001 to 4000 ppm)
- Resolution: 1 ppm
- Reaction time: 60 sec
Ambient CO:
- Measuring range: 0 to 4000 ppm
- Accuracy: +/- 20 ppm (0 to 400 ppm)/+/- 5 % of mv (401 to 2000 ppm)/+/- 10 % of mv (2001 to 4000 ppm)
- Resolution: 1 ppm
- Reaction time: 60 sec