SRL2K7 Infrared Leak Detector for Refrigerants
Unfortunately, the SRL2K7 has been discontinued and has been replaced by the DR82.
Infrared refrigerant leak detector with a sealed sensor and three sensitivity levels. Complies with SAE standards.
-With sealed sensor that doesn't "touch" the refrigerant as it passes through the instrument, lessening degregation.
-Triggers on all CFCs, HFCs, HCFCs and blends.
-Doesn't trigger on oil or moisture like other types of detectors.


- Sealed sensor. Unlike heated diode and corona discharge leak detectors, the sensor doesn't "touch" refrigerant as it passes through the instrument. Heated diode and corona discharge units tend to degrade or fail when they come in contact with high concentrations of refrigerant or touch liquid.
- Doesn't trigger on oil or moisture like other types of detectors.
- Senses change in refrigerant levels. Works even in contaminated environments.
- Rugged / Ergonomic Features. Ruggedized boot and it fit's in your hand.
- Infrared Sensor. Lasts up to 10 years.
- Three Sensitivity Levels. Plus Turbo Sensing Mode - Meets SAE standards.
- Audible/Visual Alarm. Turn the beep on or off - you decide.
- 8-hour Battery Charge. Work all day on one charge.
- Non-conductive, Sturdy Probe. Stays where you want it.
- Peak / Mute Buttons. Find leaks in noisy environments.
- Magnetic Hanger. Hang the unit while you repair the leak.
Specifications
- Sensor life: 10 years
- Refrigerants: HFC, CFC, HCFC, and blends
- Sensitivity: Min (Stationary): 0.1oz/yr (3g/yr) Max (Stationary): >1.05oz/yr (>30g/yr) Min (In motion): 0.18oz/yr (5g/yr) Max (In motion): >1.05oz/yr (>30 g/yr) After exposure to (50g/yr): 0.1 oz/yr (3g/yr) In poluted environment: 0.1 oz/yr (3g/yr)
- Response time: 1 second Recovery time: ~4 seconds Auto off: 10 minutes after no activity
- Battery: 3.7VDC(nominal), rechargeable lithium ion user-replaceable battery.
- Battery life: 8 hours continuous use prior to needing a charge. Degradation (30%) after 500 charge/discharge cycles or two years, whichever comes first.
- Low battery LED: Lights when approximately 1 hour of battery life remains.
- Charge time: Less than 4 hours (either charger)
- Operating environment: 32F (0C) to 104F (40C) at <75%RH (non-condensing)
- Storage environment: <80%RH meter and batt. For 80% battery recovery: -4F (-20C) to 140F (60C) less than 1 month -4F (-20C) to 113F (45C) less than 3 months -4F (-20C) to 68F (20C) less than 1 year
- (5) O-rings and 10 Replacement Filters - RFL2
- 9-inch Flex-Probe Extension - RFE2
- Rigid Extension Probe - RRE2
- Blow-Molded Case - ABMK3
- Operators Manual
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au