Professional Benchtop pH/mV Meter with Built-in Printer

ORDER ME IN
Product code: IC-HI122-02

Order Me In, once ordered this item will likely dispatch before the 07th of October 2025, call 1300 737 871 (NZ 0800 737 871) to confirm.

The HI122 is a professional pH/mV and temperature benchtop meter with a built-in printer. The built-in impact printer incorporated into the HI122 allows measurement information to be printed while in various modes. The meter comes with Hanna’s HI1131P glass pH electrode and an HI7662-T temperature probe to allow for automatic temperature compensation.

Regular price $2,263.80 AUD + GST
$2,490.18 AUD Inc. GST
The HI122 pH/mV and temperature benchtop meter features CAL Check, a clear and informative LCD display, data logging capability, and computer connectivity. The HI122 has a single input channel that allows for measurement of pH and ORP. Readings for pH can be manually or automatically compensated for temperature variations with the separate HI7662-T temperature probe from -20.0 to 120.0C.
The HI122 can be calibrated up to five points with a choice of seven standard buffers or two custom buffers. All GLP data regarding pH and relative mV calibration is stored for the user to review when necessary. The built-in impact printer incorporated into the HI122 allows for on demand printing of a complete set of information based on the measured, set or recorded data while in various modes such as, measurement mode, GLP or Setup mode.
Features:
- CAL Check: Hanna's exclusive CAL Check diagnostics system ensures accurate pH readings every time by alerting users of potential problems during the calibration process. The CAL Check system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated pH buffer solutions during calibration. After the guided calibration process, the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status.
- Automatic Calibration: pH calibration can be performed up to five points with seven standard buffers and two custom buffers.
- Built-in Impact Printer: The built-in impact printer incorporated into the HI122 uses regular paper that does not fade with time. The information related to measurements being taken can be printed while in measurement mode, GLP or Setup mode. This meter also allows users to print detailed information in four languages for specific help screens and instrument set-up.
- HI1131P pH Electrode: The HI122 is supplied with the HI1131P glass body, double junction, refillable pH electrode with an indicating sensor made of High Temperature (HT) glass. The double junction and HT glass design allows the HI1131P to be used in a wide variety of applications ranging from samples with metals and Tris buffer to samples at elevated temperatures.
- Temperature Compensation: Temperature for pH measurements can be compensated for automatically (ATC) or manually (MTC) from -20.0 to 120.0C with the use of the supplied HI7662-T temperature probe.
- GLP Data: The calibration data for each channel including date, time, standards used, offset, and slope can be accessed at any time through the HI122 menu.
- Data Logging: The log-on-demand feature accepts the recording of 50 samples. Interval logging allows up to 1000 data points to be recorded and allows the user to specify time intervals from 5 seconds to 180 minutes.
- Data Transfer: With a built-in logging function, measurements are stored in non-volatile memory, and can be transferred to a PC through the RS232 port.

Specifications

- pH Range: -2.00 to 16.00 pH, -2.000 to 16.000 pH
- pH Resolution: 0.01 pH, 0.001 pH
- pH Accuracy: 0.01 pH, 0.002 pH (at 25C/77F)
- pH Calibration: automatic, up to five-point calibration with seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and two custom buffers
- pH Temperature Compensation: automatic or manual from -20.0 to 120.0 C
- mV Range: 999.9 mV; 2000 mV
- mV Resolution: 0.1 mV; 1 mV
- mV Accuracy: 0.2 mV (699.9 mV); 0.5 mV (999.9 mV); 1 mV (2000 mV)
- mV Relative Offset: 2000 mV
- Temperature Range: -20.0 to 120.0 C, -4.0 to 248.0 F
- Temperature Resolution: 0.1C (0.1F)
- Temperature Accuracy: 0.4C (0.7F)
- pH Electrode: HI1131P pH electrode (included)
- Temperature Probe: HI7662-T temperature probe (included)
- Logging Type: log-on-demand; interval
- Logging Memory: 50 samples (25 per channel); 1000 samples (500 per channel)
- Logging Interval: 5 seconds to 180 minutes
- Connectivity: RS232 serial port, opto-isolated
- Printer: built-in dot matrix printer, with 44 mm plain paper
- Power Supply: 12 VDC adapter (included)
- Environment: 0 to 50C (32 to 122F), RH max 95% non-condensing
- Dimensions: 280 x 203 x 84 mm (11.0 x 8.0 x 3.3)
- Weight: 1.9 kg (4.2 lbs.)
Ordering Information:
HI122 is supplied with HI1131P pH electrode, HI7662-T temperature probe, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI7082 3.5M KCl electrolyte solution (30 mL), (5) paper rolls, 12 VDC adapter and instructions.

Our Reviews



Recently Viewed

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au