Home
>
Pool Line ORP/pH/Temperature Tester - IC-HI981214
Pool Line ORP/pH/Temperature Tester - IC-HI981214
ORDER ME IN
Backorder Now, once ordered your item will dispatch before the 23rd of June 2025, call 1300 737 871 (NZ 0800 737 871 to confirm).
The HI981214 Pool Line Combo pH/ORP meter is made for measuring pH and ORP of a swimming pool, hot tub, or spa water.
- - Gives you highly accurate measurements of pH, ORP and temperature. No more switching between meters for your routine measurements.
- - Waterproof with replaceable electrode.
Regular price
$405.42 AUD
+ GST
$445.97 AUD Inc. GST
$445.97 AUD Inc. GST




The HI981214 Pool Line Combo tester is a highly accurate, waterproof pH meter that can also measure ORP and temperature. This floating, waterproof combination tester has an easy to read, LCD and an automatic shut-off. All pH readings are automatically temperature compensated (ATC) for variations in temperature.
It is ideal for checking the pH and disinfection levels of swimming pools, hot tubs, and spas. The accurate reading of pH is critical to ensure that the chlorine is in predominately the hypochlorous acid form instead of the hypochlorite form, which is less effective at killing bacteria. The ideal pH for a pool is between 7.2 and 7.4.
The ORP portion of the meter is used to monitor the disinfection level of the pool to always be sure that there is enough chlorine present to keep bathers safe from bacteria. The ideal ORP reading is +650 mV. At this voltage any bacteria will be inactivated in a short time. It is important to note that if a stabilizer such as cyanuric acid is used that the stabilizer as a reducing agent will mask the oxidation potential of chlorine. ORP should not be used when chlorine is introduced as solid puck since it is likely that it will have stabilizers as well.
The HI981214 tester features an easy to replace pH electrode cartridge with an extendable cloth junction. The extendable cloth junction helps increase electrode life and the replaceable pH cartridge means that this tester does not need to be thrown away when the pH sensor is exhausted. Also, the sturdy, snap-in connector means there are no pins to bend or break!
Features:
- 3 sensors in a single meter: pH electrode with extractable junction, ORP electrode, and Temperature probe for pH temperature compensated measurements
- Waterproof: Designed to float if accidently dropped in sample
- Wide Range: pH range is from -2.00 to 16.00 pH and ORP range of 1000 mV
- Automatic Temperature Compensation: All pH readings are compensated for variations in temperature
- Temperature displayed in C or F along with pH or ORP reading
- Stability indicator: Meter displays a clock tag that will disappear when the reading has achieved stability
- HOLD button: Freezes reading on the display to allow recording of measurement
- BEPS (Battery Error Prevention System: Meter will automatically shut off if there is not enough power to get an accurate measurement
- Battery % level at startup / Low Battery Indicator
- Auto-off: Auto-off feature automatically shuts off the meter after 8 minutes of non-use to maximize battery life
- Waterproof: Designed to float if accidently dropped in sample
- Wide Range: pH range is from -2.00 to 16.00 pH and ORP range of 1000 mV
- Automatic Temperature Compensation: All pH readings are compensated for variations in temperature
- Temperature displayed in C or F along with pH or ORP reading
- Stability indicator: Meter displays a clock tag that will disappear when the reading has achieved stability
- HOLD button: Freezes reading on the display to allow recording of measurement
- BEPS (Battery Error Prevention System: Meter will automatically shut off if there is not enough power to get an accurate measurement
- Battery % level at startup / Low Battery Indicator
- Auto-off: Auto-off feature automatically shuts off the meter after 8 minutes of non-use to maximize battery life
Specifications
- pH Range: -2.00 to 16.00 pH
- pH Resolution: 0.01 pH
- pH Accuracy: +/- 0.05 pH
- pH Calibration: automatic, one or two-point with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
- pH Temperature Compensation: automatic
- ORP Range: +/- 1000 mV
- ORP Resolution: 1 mV
- ORP Accuracy: +/- 2 mV
- Temperature Range: -5.0 to 60.0 C
- Temperature Accuracy: +/- 0.5 C
- pH Electrode: HI73127
- Automatic: Shut-Off After 8 minutes of non-use
- Battery Type/Life: 1.5V (4)/ Approximately 250 hours
- Environment: -5 to 50 C; RH 100%
- Dimensions: 171 x 41 x 26 mm
- Weight: 83 g
Ordering Information
The HI981214 is supplied with HI700044 pH 4.01 buffer solution, 20 mL sachet (1 pc.), HI700074 pH 7.01 buffer solution, 20 mL sachet (1 pc.), HI7003004 storage solution for pH & ORP electrodes, 20 mL sachet (1 pc.), HI700224 470 mV ORP test solution, 20 ml sachet (2 pcs.), HI7006014pH & ORP electrode cleaning solution, 20 mL sachet (1 pc.), HI73127 pH electrode, HI73128 Electrode removal tool, storage/protection cap, 1.5V batteries (4 pcs.), instrument quality certificate, and instruction manual.
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au