The CO2 Analyzer PCE-RCM 12 is used for indicative testing of environmental parameters. The CO2 Analyzer PCE-RCM 12 enables the measurement of CO2, fine dust, temperature and relative humidity. The bright display of the CO2 Analyzer provides information about these parameters. Environmental monitoring can be done continuously with the CO2 Analyzer for up to five hours without the device being connected to a power source.
For permanent measurement, the CO2 Analyzer can be connected to AC power via a USB interface. The rechargeable battery will be recharged within two hours if the air quality monitor is turned off. When measuring carbon dioxide, the meter has a wide measuring range from 0 to 9,999 ppm. The display of the concentrations is further facilitated by the use of a color rating scale, as this provides direct information about the air quality to the user.
In addition to the indicative measurement of formaldehyde, which can be harmful to health, an indicative measurement of particulate matter pollution can also be carried out. A distinction is made between particles with a maximum diameter of up to 10 um (PM10) and particles up to a diameter of 2.5 um (PM2.5).
Features:
- Measurement of CO2 and formaldehyde
- Indication of room temperature and humidity
- Particulate matter measurement (PM2.5 / PM10)
- Large CO2 measurement range up to 9999 ppm
- Changing display of the measured values
- Memory for up to 5000 measuring groups
- Date and time display
- 3 inch large TFT-LCD display
- Safe and easy handling
Specifications
Fine Dust:
- Measuring range: PM2.5 / PM10
- Measuring range particle measurement: 0 to 2000 ug/m3
- Resolution particle measurement: 1 ug/m3
Carbon Dioxide:
- Measuring range: 0 to 9999 ppm
- Accuracy: +/- 5% of measured value or +/- 75 ppm
- Resolution: 1 ppm
Formaldehyde:
- Measuring range: 0.00 to 5.00 mg/m3
- Accuracy: +/- 5% of measured value
- Resolution: 0.01 mg/m3
Humidity:
- Measuring range: 0 to 100%RH
- Accuracy: +/- 3.5%RH (at 20 to 80%RH), +/- 5%RH (at 0 to 20%RH/ 80 to 100%RH)
- Resolution: 0.1%RH
Temperature:
- Measuring range: -20 to 70 C
- Accuracy: +/- 2 C
- Resolution temperature: 0.1 C
General:
- Sound sensor: Wake up function to APO
- Power supply: 2400-mAh, rechargeable battery
- Battery life: Continuous measurement for up to 5 hours
- Charging: Via USB 5V / 1 A
- Charging time: 2 hours (when switched off)
- Automatic sleep mode: Adjustable if necessary
- Display: 3 inch TFT LCD Display, 240 x 400 pixel
- Data storage: 5000 measurement groups
- Operating temperature: 0 to 50 C
- Storage temperature: -10 to 60 C
- Dimensions: 85 x 75 x 155 mm
- Weight: 360 g