The multi-parameter water analysis meter is a mobile measuring device for liquid analysis. This enables the most varied of measurements to be carried out with the multi-parameter photometer. With this multi-parameter photometer, for example, it is possible to determine alkalinity, chlorine, cyanuric acid or the pH value. In order to carry out a measurement with the multi-parameter photometer, a water sample of 10 ml must be placed in a cuvette. The built-in LED in the multi-parameter photometer generates a test light in the wavelength ranges of 503 nm, 570 nm and 620 nm. A photodiode now recognizes the value to be measured based on the light transmission of the sample.
Each measurement is automatically saved by the multi-parameter water analysis meter. The stored measured values can then be read out, for example, via a mobile device via the Bluetooth interface built into the multi-parameter photometer. A free app is available to analyze the measured values from the multi-parameter photometer. It is also possible to establish a Bluetooth connection between the multi-parameter photometer and a computer. Free software is also available for this, with which the measurement data can be analyzed. As another special feature of the multi-parameter photometer, the measurement data can be uploaded to a cloud using both variants and accessed from anywhere. This service for the multi-parameter photometer is also free of charge.
Features:
- Up to 5 selectable parameters
- Bluetooth connection with app
- Exchangeable and lockable cuvette
- 503 nm / 570 nm / 620 nm LED
- Automatic shutdown when inactive
- Many different menu languages
- Light detector: photodiode
- Cuvette: 36 x 21 diameter mm (10 ml)
Specifications
Alkalinity:
- Measuring range: 0 to 30 mg / l; 30 to 60 mg / l; 60 to 100 mg / l; 100 to 200 mg / l
- Accuracy: 3 mg / l; 7 mg / l; 12 mg / l; 18 mg / l
- Resolution: 1 mg / l
pH:
- Measuring range: 6.50 to 8.40 pH
- Accuracy: 0.11 pH
- Resolution: 0.01 pH
Total hardness:
- Measuring range: 0 to 30 mg / l; 30 to 60 mg / l; 60 to 100 mg / l; 100 to 200 mg / l; 200 to 300 mg / l; 300 to 500 mg / l
- Accuracy: 3 mg / l; 5 mg / l; 10 mg / l; 17 mg / l; 22 mg / l; 58 mg / l
- Resolution: 1 mg / l
Calcium hardness:
- Measuring range: 0 to 25 mg / l; 25 to 100 mg / l; 100 to 300 mg / l; 300 to 500 mg / l
- Accuracy: 8 mg / l; 22 mg / l; 34 mg / l; 45 mg / l
- Resolution: 1 mg / l
Other specifications:
- Hardness units: mg/l CaCO3, ppm, mmol/l KS 4.3, dH (degree of German hardness), e (degree English hardness / Degree Clark), f (degree of French hardness)
- Calibration: Zero point calibration
- Light source: 503 nm / 570 nm / 620 nm LED
- Light detector: Photodiode
- Power supply: 4x 1.5V AA batteries
- Dimensions of the cuvette: 36 x 21 diameter mm
- Menu languages: English, German, French, Spanish and Italian
- Storage: Automatic storage of measured values and readout
- Storage space: 256 values
- Interface: Bluetooth connection with app and PC software
- Automatic shutdown: After 300 seconds of inactivity
- Operating conditions: 5 to 45 C, 20 to 90% RH non-condensing
- Storage conditions: 5 to 45 C, 20 to 90% RH non-condensing
- Dimensions: 165 x 95 x 50 mm
- Weight: 230 g