Milesight AM319 - Indoor Air Quality 9 in 1 with Ozone LoRaWAN Sensor
Order Me In, Once ordered this item will likely dispatch before the 17th of November 2025, call 1300 737 871 (NZ 0800 737 871) to confirm.
The AM319-915M-O3 is a compact indoor ambience monitoring sensor for measurement of Temperature, Humidity, PIR, Light, TVOC, Barometric Pressure, Carbon Dioxide (CO2), Particulate Matter (PM2.5 & PM10), formaldehyde and ozone.
- Recorded readings are displayed in real-time through a 4.2 inch E-ink screen.
- Sensor data is transmitted using LoRaWAN
- Manage all sensor data remotely and visually through the Cloud when used with Milesight's gateways
$615.01 AUD Inc. GST




Specifications
Frequency
|
CN470/RU864/IN865/EU868/US915/AU915/KR920/AS923-1&2&3&4
|
Tx Power
|
16dBm(868MHz)/22dBm(915MHz)/19dBm(470MHz)
|
Sensitivity
|
-137dBm at 300bps
|
Work Mode
|
OTAA/ABP Class A
|
Temperature
|
Sensor
|
Operating Principle
|
Digital CMOSens technology (MEMS)
|
Range
|
-20 to 60 C
|
Accuracy
|
+/- 0.2 C
|
Resolution
|
0.1 C
|
Humidity
|
Sensor
|
Operating Principle
|
Digital CMOSens technology (MEMS)
|
Range
|
0% - 100% RH
|
Accuracy
|
+/- 2% RH
|
"Resolution "
|
0.5% RH
|
Motion
|
Sensor
|
Operating Principle
|
Passive infrared (PIR)
|
"Detection Range "
|
80 degrees Horizontal, 55 degrees Vertical, 5m
|
Status
|
Vacant/Occupied
|
Light
|
Sensor
|
Operating Principle
|
Photodiode
|
Range
|
0-60000 Lux (Determine as 6 levels, 0-5)
|
TVOC
|
Sensor
|
Operating Principle
|
MOX (MEMS)
|
Range
|
1.00 - 5.00 (IAQ Rating)
|
Accuracy
|
+/- 1
|
Resolution
|
0.01
|
Barometric Pressure
|
Sensor
|
Operating Principle
|
Piezoresistive absolute pressure sensor (MEMS)
|
Range
|
260 - 1260 hPa
|
Accuracy
|
+/- 0.5 hPa
|
Resolution
|
0.1 hPa
|
Carbon Dioxide
|
Body cell
|
Operating Principle
|
Nondispersive Infrared (NDIR)
|
Range
|
400 - 5000 ppm
|
Accuracy
|
+/- (30 ppm + 3 % of reading) (0 to +50 C)
|
Resolution
|
1 ppm
|
PM2.5 & PM10
|
Body cell
|
Operating Principle
|
Laser Scattering
|
Range
|
0 - 1000 ug/m3
|
Accuracy
|
0-100 (+/- 10ug/m3), 100-1000(+/- 10%); (-10 C to +60 C)
|
Resolution
|
1 ug/m3
|
Formaldehyde (HCHO)2
|
Body cell
|
Operating Princicple
|
Electrochemical
|
Range
|
0 - 1.25 mg/m3 (760 mmHg and 20 C, 1 ppm = 1.25 mg/m3)
|
Accuracy
|
+/- 10 %
|
Resolution
|
0.01 mg/m3
|
"Working Life "
|
6 Years
|
Ozone
|
Body cell
|
Range
|
0 - 10 ppm
|
Accuracy
|
+/- 5 %FS
|
Resolution
|
0.01 ppm
|
"Working Life "
|
2 Years
|
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au