The Fluke 1507 Insulation Testers is compact, rugged, reliable, and easy to use. With its multiple test voltages, it is an ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.Additional features, like the remote probe on these tools save both time and money when performing tests.
Regular price
$1,238.00 AUD
+ GST
$1,361.80 AUD Inc. GST
$1,361.80 AUD Inc. GST




Insulation test range: 0.01 M? to 10 G?
Insulation test voltages: 1507: 50 V, 100 V, 250 V, 500 V, 1000 V? to 10 G?
Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio (only available on the1507)
Make repetitive tests simple and easy with the 1507’s Compare (Pass/Fail) function (only available on the 1507)
Repetitive or hard-to-reach testing is easy with the remote test probe
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage: 0.1 V to 600 V
200 mA Continuity
Resistance: 0.01 ? to 20.00 k?
Save battery power with auto power off
Read measurements easily with large, backlit display
CAT IV 600 V overvoltage category rating for added user protection
Remote probe, test leads, probes and alligator clips included with each tester
Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
One year warranty
Specifications
AC/DC range: 600.0 V
AC/DC resolution: 0.1 V
Accuracy: 50 Hz to 400 Hz ± (% of Rdg + Digits), ± (2 % + 3)
Input impedance: 3 MO (nominal), < 100 pFCommon mode rejection ratio (1 kO unbalanced): > 60 dB at dc, 50 or 60 Hz
Overload Protection: 600 V rms or dc
Earth bond resistance measurement range/resolution: 20.00 O/0.01 O, 200.0 O/0.1 O, 2000 O/1.0 O, 20.00 kO/0.01 kO
Earth bond resistance measurement accuracy: ± (1.5 % + 3)
Overload protection: 2 V rms or dc
Open circuit test voltage: > 4.0 V, < 8 V
Short circuit current: > 200.0 mA
Insulation specifications:
Measurement Range: 0.01 MΩ to 10 GΩ
Test voltage: 50 V, 100 V, 250 V, 500 V, 1000 V
Test Voltage Accuracy: + 20 %, - 0 %
Short circuit current: 1 mA nominal
Auto discharge: Discharge time < 0.5 second for C = 1 µF or less
Live circuit indicator: Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive load: Operable with up to 1 µF load
Measure Accuracy: 50 V: ±(3 % + 5), 100 V: ±(3 % + 5), 250 V: ±(1.5 % + 5), 500 V: ±(1.5 % + 5), 1000 V:±(1.5 % + 5) to 2000 MO, ±(10 % + 3) above 2000 MO
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au