INDUSTRIAL MULTIMETER - IC-FLUKE-83-5
ORDER ME IN
Order Me In, once ordered this item will likely dispatch before the 11th of September 2025, call 1300 737 871 (NZ 0800 737 871) to confirm.
Fluke 83V Industrial Digital Multimeter (Analog Bargraph, Digital Display, Backlight, 1000VAC/DC, Measure up to 10 A, 20 A for up to 30 seconds)
Regular price
$963.00 AUD
+ GST
$1,059.30 AUD Inc. GST
$1,059.30 AUD Inc. GST




Features:
6000 counts, 3-3/4 digits
Measure up to 1000 V ac and dc
Measure up to 10 A, 20 A for up to 30 seconds
Frequency to 200 kHz and % duty cycle
Resistance, continuity and diode test
10,000 µF capacitance range for components and motor caps
Min/Max-Average recording with Min/Max Alert to capture variations automatically
Peak capture to record transients as fast as 250 µs
Relative mode to remove test lead interference from low ohms measurements
Auto and manual ranging for maximum flexibility
Touch Hold to capture stable readings avoiding noisy signals
Large display digits and two-level bright white backlight for increased visibility
Analog bargraph for fast changing or unstable signals
Input Alert provides audible warning against wrong use of input jacks
Improved selectable sleep mode for long battery life
Access door for fast battery changes without breaking the calibration seal
"Classic" design with new removable holster with built in test lead and probe storage
Lifetime warranty
Voltage (DC) maximum voltage: 1000V
Voltage (DC) accuracy: ±(0.1%+1)
Voltage (DC) maximum resolution: 100 µV
Voltage (AC) maximum voltage: 1000V
Voltage (AC) Accuracy: ±(0.5%+2) True RMS
Voltage (AC) Bandwidth: 5kHz
Current (DC) maximum Amps: 10A (20 A for 30 seconds maximum)
Current (DC) Amps Accuracy: ±(0.4%+2)
Current (DC) maximum resolution: 0.01 mA
Current (AC) maximum Amps: 10A (20 A for 30 seconds maximum)
Current (AC) Amps accuracy: ±(1.2%+2)
Current (AC) maximum resolution: 0.1 µA
Resistance: 50 MO
Resistance accuracy and resolution: ±(0.4%+1). 0.1O
Maximum Capacitance" 9,999 µ
Capacitance accuracy and resolution: ±(1%+2), 0.1O
Maximum Frequency: 200 kHz
Frequency accuracy: ±(0.005%+1)
Maximum Resolution: 0.01 Hz
Temperature Measurement: -200.0°C - 1090°C (-328.0°F - 1994.0°F)
Maximum conductance: 60.00 nS
Conductance accuracy and resolution: ±(1.0%+10), 0.1%
6000 counts, 3-3/4 digits
Measure up to 1000 V ac and dc
Measure up to 10 A, 20 A for up to 30 seconds
Frequency to 200 kHz and % duty cycle
Resistance, continuity and diode test
10,000 µF capacitance range for components and motor caps
Min/Max-Average recording with Min/Max Alert to capture variations automatically
Peak capture to record transients as fast as 250 µs
Relative mode to remove test lead interference from low ohms measurements
Auto and manual ranging for maximum flexibility
Touch Hold to capture stable readings avoiding noisy signals
Large display digits and two-level bright white backlight for increased visibility
Analog bargraph for fast changing or unstable signals
Input Alert provides audible warning against wrong use of input jacks
Improved selectable sleep mode for long battery life
Access door for fast battery changes without breaking the calibration seal
"Classic" design with new removable holster with built in test lead and probe storage
Lifetime warranty
Specifications
Voltage (DC) maximum voltage: 1000V
Voltage (DC) accuracy: ±(0.1%+1)
Voltage (DC) maximum resolution: 100 µV
Voltage (AC) maximum voltage: 1000V
Voltage (AC) Accuracy: ±(0.5%+2) True RMS
Voltage (AC) Bandwidth: 5kHz
Current (DC) maximum Amps: 10A (20 A for 30 seconds maximum)
Current (DC) Amps Accuracy: ±(0.4%+2)
Current (DC) maximum resolution: 0.01 mA
Current (AC) maximum Amps: 10A (20 A for 30 seconds maximum)
Current (AC) Amps accuracy: ±(1.2%+2)
Current (AC) maximum resolution: 0.1 µA
Resistance: 50 MO
Resistance accuracy and resolution: ±(0.4%+1). 0.1O
Maximum Capacitance" 9,999 µ
Capacitance accuracy and resolution: ±(1%+2), 0.1O
Maximum Frequency: 200 kHz
Frequency accuracy: ±(0.005%+1)
Maximum Resolution: 0.01 Hz
Temperature Measurement: -200.0°C - 1090°C (-328.0°F - 1994.0°F)
Maximum conductance: 60.00 nS
Conductance accuracy and resolution: ±(1.0%+10), 0.1%
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au