Monitor Indoor Air Quality (IAQ) in public spaces with potentially high levels of CO2 (carbon dioxide)
Regular price $937.27 AUD + GST
$1,031.00 AUD Inc. GST
Poor air quality may cause tiredness, inability to concentrate, and even illness (i.e., Sick Building Syndrome). This instrument is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of CO2 (carbon dioxide) such as offices, factories, classrooms, hospitals and hotels.
The same measurement parameters can also be used to test air from HVAC equipment. Backlit simultaneous display of CO2 level, humidity and air temperature, or the user may choose a rotating display of dew point and wet bulb temperature instead of air temperature. Also calculates TWA (Time Weighted Average) and STEL (Short-Term Exposure Limit). Simple user calibration of CO2 and RH. Features audible CO2 threshold alarms, min/max/avg, hold and a computer interface.
Measures
- CO2
- Humidity
- Dew Point
- Air Temperature
- Wet Bulb Temperature

Specifications

Air temperature
- Range: -10 to 60 C (14 to 140 F)
- Resolution: 0.1
- Accuracy: 0.6 C/0.9 F
RH
- Range: 0 to 100%
- Resolution: 0.1
- Accuracy: +/- 3% (10 to 90%) +/- 5% (otherwise)
Dew Point
- Range: -13.3 to 60 C (8 to 140 F)
- resolution: 0.1
Wet Bulb
- Range: -73.4 to 60 C (-100 to 140 F)
- Resolution: 0.1
Carbon dioxide
- Range: 0 to 5000 ppm
- Resolution: 1 ppm
- Accuracy: +/- 30 ppm +/- 5% rdg
Carbon Dioxide (CO2) Levels and Exposure Effects
- 250 to 350 ppm: Background (normal) outdoor air level.
- 350 to 1,000 ppm: Typical level found in occupied spaces with good air exchange.
- 1,000 to 2,000 ppm: Level associated with complaints of drowsiness and poor air.
- 2,000 to 5,000 ppm: Level associated with headaches, sleepiness, and stagnant, stale, stuffy air. Poor concentration, loss of attention, increased heart rate and slight nausea may also be present.
- 5,000 ppm: Exposure may lead to serious oxygen deprivation resulting in permanent brain damage, coma and even death.
Video: Unboxing the IC-800046 Indoor Air Quality Meter 

Our Reviews



Recently Viewed

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au