HOBO U-Shuttle - U-DT-1 - IC-U-DT-1

DISCONTINUED
Product code: IC-U-DT-1

Unfortunately, the IC-U-DT-1 has been discontinued, check out our other HOBO Accessories for more options

Conveniently offload data in the field with the HOBO U-Shuttle Data Transporter. This product also allows users to easily relaunch HOBO U-series data loggers and HOBO Weather Stations, Micro Stations, and HOBO Energy Logger systems. View readings on a 2 x 16-character display for selected data loggers, and access logger status for all loggers. An Optic USB Base Station is required for use with optic USB data loggers.

Specifications



Operating temperature: 0 to 50C (32 to 122F).
Storage temperature :-10 to 50C (14 to 122F).
Time accuracy: 1 minute per month at 25C (77F); see Plot A.
Logger-to-shuttle transfer speed (USB/optic): 64K in approximately 30 seconds.
Logger-to-shuttle transfer speed (Serial): 512K in approximately 60 seconds.
Shuttle-to-host transfer speed: Full shuttle offload (4 MB) to host computer in 3 to 5 minutes, depending on computer.
Data capacity (full loggers): 4 MB (minus 64 KB for shuttle information): enough for 504 readouts of 8K loggers, 63 readouts of 64K loggers, or 7 readouts of 512K loggers.
Idle timeout: Shuttle powers down after two minutes of idle time, except when actively communicating with HOBOware or changing logger batteries (10 minutes).
Clock backup: 1 CR1225 lithium battery (3 V).
Battery life Main: One year or approximately 50 complete memory fills, typical use.
Clock backup: 10 years typical use (with main batteries installed).
Case materials: ABS case with urethane rubber grips, polycarbonate label.
Firmware upgrades: Available on the Onset website as needed to provide compatibility with future supported logger models.

Requirements:


HOBOware Pro 2.2.0 or greater; USB cable (provided)
Compatible logger with appropriate cable and/or base station
Compatibility: All U-Series loggers, HOBO Weather Stations and Micro Stations (H21), and HOBO FlexSmart loggers (H22); not compatible with the HOBO Waterproof Shuttle (U-DTW-1).

Ports:

RJ-12 jack for communicating with smart sensors.
mini-B full speed USB port for communicating with host computer.
full speed USB port for communicating with U-Series loggers and base stations.
high speed serial port for communicating with serial loggers.
Shuttle communicates with only one device at a time.

Our Reviews



Recently Viewed

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au