HI99300 EC/TDS/Temperature Meter

ORDER ME IN
Product code: IC-HI99300

Backorder Now, once ordered your item will dispatch before the 02nd of June 2025, call 1300 737 871 (NZ 0800 737 871 to confirm).

The HI99300 is a rugged, portable EC/TDS and temperature meter housed in a case rated for IP67 conditions.

  • - Supplied with a two-ring conductivity probe to allow for low range EC measurements (0 to 3999 uS/cm) and TDS (0 to 2000 ppm).
  • - With Automatic Temperature Compensation.
  • - Users are able to adjust the temperature correction coefficient and TDS factor.

Regular price $406.25 AUD + GST
$446.88 AUD Inc. GST
The portable, waterproof Portable Low Range EC/TDS Meter - HI99300 is suitable for use in applications as diverse as wastewater treatment, reverse osmosis, and HVAC. It measures low range conductivity in uS/cm and TDS in ppm. The HI763063 EC/TDS probe is a two-ring sensor that resists clogging and is easy to clean. The probe also features a built-in temperature sensor to allow for Automatic Temperature Compensation from 0 to 60 C (32 to 140 F).
The meter easily fits in the palm of your hand and the bottom probe connection ensures the electrode cable doesnt get in the way. The large, multi-level LCD displays the primary reading, temperature, and calibration guides simultaneously. Symbols and messages on the LCD indicate meter status and guides users through operations.
3 Year Warranty (2 Year Manufacturer Warranty + Bonus 1 Year Instrument Choice Warranty)
HI99300 Features
- Two-ring Probe - The HI763063 is a two-pole probe that comes with the HI99300, offering an accurate solution for low range EC and TDS readings. The probe features a built-in temperature probe to allow for temperature compensated readings.
- Two Measurement Modes - HI99300 offers two measurement modes: EC and TDS. Users can easily switch between measurement modes with a simple press of the MODE button. EC measurements range from 0 to 3999 S/cm; TDS measurements range from 0 to 2000 ppm.
- Adjustable TDS Factor - The TDS value in aqueous solutions is directly proportional to conductivity. The ratio between the two parameters depends on the solution being measured. The HI99300 has an adjustable TDS factor from 0.45 to 1.00 with 0.01 intervals, allowing users to choose the conversion factor that is the most appropriate for their particular solution.
- Automatic Temperature Compensation - Since temperature has such a dramatic effect on conductivity and TDS readings, having a meter that offers temperature compensated readings is invaluable. The probe of the HI99300 features a built-in temperature sensor that automatically accounts for the effects of temperature in the range of 0 to 60 C (32 to 140 F).
- Adjustable Temperature Compensation Coefficient - The temperature compensation coefficient, also known as B, is adjustable from 0.0 to 2.4%/C with 0.1% intervals; this factor corrects the reading a set percentage % for each degree Celsius change in the sample.
- Automatic Calibration - The HI99300 can be automatically calibrated at one point in a standard EC or TDS solution. A 1413 uS/cm standard is used for EC calibration, which will automatically calibrate TDS readings. However, if the meter is in TDS mode and set to either 0.5 or 0.7 conversion factor, a direct calibration in 1382 ppm or 1500 ppm (using 0.5 or 0.7 conversion factor, respectively) TDS calibration solution can be used.
- Battery Error Prevention System (BEPS) - The Battery Error Prevention System detects when the batteries become too weak to ensure reliable measurements.
- Instability Indicator - The HI99300 displays a clock tag that will disappear when a reading has achieved stability.
Standard package includes:
The HI99300 is supplied with HI763063 EC/TDS probe, HI70031 1413 uS/cm calibration solution sachet (1), HI70032 1382 ppm calibration solution sachet (1), 100 mL beaker, batteries, calibration certificates for both meter and probe, instruction manual, and rugged thermoformed carrying case.

Specifications

- EC Range:
0 to 3999 uS/cm
- EC Resolution:
1 uS/cm
- EC Accuracy:
+/- 2% FS
- EC Calibration:
manual, one-point through TDS knob
- TDS Range:
0 to 2000 ppm (mg/L)
- TDS Resolution:
1 ppm (mg/L)
- TDS Accuracy:
+/- 2% F.S.
- TDS Calibration:
automatic, one point at 1382 ppm (CONV 0.5) or 1500 ppm (CONV 0.7)
- EC/TDS Temperature Compensation:
automatic, 0 to 60 C (32 to 140 F) with B adjustable from 0.0 to 2.4%/C with 0.1% step
- Temperature Correction Coefficient:
automatic, with b selectable from 0.0 to 2.4 %/ C with 0.1 increments
- EC to TDS Conversion Factor:
selectable from 0.45 to 1.00 (CONV)
- Temperature Range:
5.0 to 105.0 C / 23.0 to 221.0 F
- Temperature Resolution:
0.1 C / 0.1 F
- Temperature Accuracy:
+/- 0.5 C / +/- 1 F
- EC/TDS Probe:
HI763063 with built-in temperature sensor, quick connect DIN connector and 1 m cable (included)
- Automatic Shut-Off:
user selectable
- Battery Type/Life:
1.5V AAA (3) / approximately 500 hours of continuous use
- IP Protection:
IP67
- Environment:
0 to 50 C (32 to 122 F); RH max 100%
- Dimensions:
154 x 63 x 30 mm (6.1 x 2.5 x 1.2)
- Weight:
196 g (6.91 oz.)

Our Reviews



Recently Viewed

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au