HI98703, Turbidity Meter
Order Me In, once ordered this item will likely dispatch before the 12th of October 2025, call 1300 737 871 (NZ 0800 737 871) to confirm.
$2,487.91 AUD Inc. GST




- High accuracy at low ranges (below 0.05 NTU)
- Two, three or four point calibration
- USB and RS232 PC connectivity
- Log up to 200 records
- GLP Features
- User friendly, backlit display with guidance codes
- Battery % on startup
- Continuous current time on display
The HI 98703 meets and exceeds the requirements of the USEPA Method 180.1 for wastewater and Standard Method 2130 B for drinking water. The instrument has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels.
This instrument incorporates complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration
points,
time and date can be checked at the touch of a button.
With it's logging function, up to 200 measurements along with it's tagged locations can be stored in internal memory and consulted at any time. Data can be later transferred to a PC via RS232 or USB interface and HANNA HI 92000 software (optional).
Exclusive Fast Tracker
For advanced field applications, the HI 98703 is equipped with Fast Tracker Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker allows users to record the time and location of a specific measurement or series of measurements.
Range: 0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU
Range Selection: automatic
Resolution: 0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU
Accuracy at 25 C: ?2% of reading plus 0.02 NTU
Repeatability: ?1% of reading or 0.02 NTU, whichever is greater
Stray Light: < 0.02 NTU
Light Detector: silicon photocell
Light Source: tungsten filament lamp
Lamp Life: greater than 100,000 readings
Method: Ratio Nephelometric Method (90 ), ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B
Measuring Mode: normal, average, continuous
Turbidity Standards: <0.1, 15, 100 and 750 NTU
Calibration: two, three or four-point calibration
Log Memory: 200 records
PC Connectivity: USB or RS232
Environment: up to 50 C (122 F); RH max 95% non-condensing
Power Supply: 1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use
Dimensions / Weight: 224 x 87 x 77 mm (8.8 x 3.4 x 3.0") / 512 g (18 oz.)
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au