HI88713, Turbidity Benchtop Meter, ISO
Order now and the extra items will likely dispatch before the 12th Feb 2026. Call 1300 737 871 (NZ 0800 737 871) to confirm.
$4,479.00 AUD Inc. GST
The HI 88713 turbidity bench meter meets and exceeds the requirements of the
ISO 7027 standard.
HI 88713 is based on an optical system which guarantees accurate results, long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the LED, limiting the need for frequent calibration.
Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.
A two, three, four or five-point calibration can be performed using the supplied standards. Calibration points can be modified when user prepared standards are used.
The HI 88713 turbidity bench meter has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions.
The HI 88713 turbidity bench meter has a user-friendly interface with an easy to understand, graphic LCD. Comprehensive contextual help is available at a simple key press. Furthermore, a tutorial mode of operation guides the user step by step through the analysis process.
Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows compatible software.
Range:
FNU Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 FNU
FAU Mode 10.0 to 99.9; 100 to 4000 FAU
NTU Ratio Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC
NTU Non-Ratio Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 245 EBC
Resolution:
FNU Mode 0.01; 0.1; 1 FNU
FAU Mode 0.1; 1 FAU
NTU Ratio Mode 0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
NTU Non-Ratio Mode 0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
Accuracy at 25 C:
FNU Mode ±2% of reading plus stray light
FAU Mode ±10% of reading
NTU Ratio Mode ±2% of reading plus stray light / ±5% of reading above 1000 NTU
NTU Non-Ratio Mode ±2% of reading plus stray light
Range Selection: automatic
Repeatability: ±1% of reading or stray light, whichever is greater
Stray Light: < 0.1 NTU (0.05 EBC)
Light Detector: silicon photocell
Light Source: IR LED
Method: ISO 7027 Method
Measuring Mode: normal, average, continuous.
Turbidity Standards: <0.1, 15, 100, 750 FNU and 2000 NTU
Calibration: two, three, four or five-point calibration
Log Memory: 200 records
PC Connectivity: USB
Environment: 0 C (32 F) to 50 C (122 F); max 95% RH non-condensing
Power Supply: 12 Vdc power input
Dimensions / Weight: 230 x 200 x 145 mm (9 x 7.9 x 5.7") / 2.5 Kg (88 oz.)
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au