How to Calibrate the EC-SaltTestr11 Waterproof Salt Meter

How to Calibrate the EC-SaltTestr11 Waterproof Salt Meter

The design of the EC-SaltTestr11 Waterproof salinity meter enables quick and accurate salinity measurements. This user-friendly meterguarantees years of trouble-free operation and requires very little maintenance. One critical step to keep this meter performing to the highest level of accuracy is to perform regular calibration. Thankfully, calibration of the EC-SaltTestr11 is an incredibly simple task that takes only eight steps.

 
Figure 1 Watch an Instrument Choice unbox and demonstrate how to calibrate the EC-SaltTestr11 Salinity Meter here.

How to Calibrate the EC-SaltTestr11 Waterproof Salt Meter

You will need:

Method

  1. Half fill both the containers with the NaCI calibration solution. One container is for pre-rinsing, and the other is to perform the calibration.
  2. Start with the meter switched on and in measurement mode.
  3. Remove the cap on the top of the device. Under the cap is the two buttons required for calibration, these are increase and decrease selection.
  4. Remove the end cap covering the electrode and then rinse the electrode in the first container of the calibration standard.
  5. Move the electrode into the second container of the calibration solution and swirl gently to create a homogenous sample. Allow some time for the reading to stabilise.
  6. Press the increase or decrease button to enter the calibration mode. 'CAL' will appear on the top of the LCD. When in calibration mode, the upper display shows the measured reading of the solution based on previous calibrations (if any), and the lower display shows the default uncalibrated reading.
  7. Use the increase and decrease buttons to adjust the upper display to the correct value of the calibration solution.
  8. After adjusting to match the calibration solution value, press no buttons and wait five seconds for the tester to confirm the calibration by displaying 'CO' automatically.
  9. The salinity meter will then automatically return to measurement mode, and the calibration is complete. Replace the top lid, and the meter is ready to take accurate salinity measurements.

Conclusion

The EC-SaltTestr11 is a straightforward salinity meter that can simply be user calibrated to ensure consistently accurate measurements. If you would like more information on the EC-SaltTestr11 salinity meter or want to know more about salinity calibration solutions, see the additional links (below) or contact us!

Additional links

See our other newsletter articles here!

Contact our expert scientists now to get the right meter or data logger to suit your needs and discuss your project. 

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au