Manual Calibration Dissolved Oxygen Meter - IC-HI9142

ORDER ME IN
Product code: IC-HI9142

Backorder Now, once ordered your item will dispatch before the 09th of June 2025, call 1300 737 871 (NZ 0800 737 871 to confirm).

The HI9142 is a rugged, portable, waterproof dissolved oxygen (DO) meter, with replaceable polytetrafluoroethylene (PTFE) membrane caps and protective shield, designed to provide reliable measurements under harsh environmental conditions. 

  • - Includes complete with polarographic probe and replaceable PTFE membrane caps.
  • - Waterproof.
  • - Manual one or two point calibration at 100% and automatic calibration in zero oxygen solution.
Regular price $1,029.00 AUD + GST
$1,131.90 AUD Inc. GST
The HI9142 is a rugged, portable, waterproof dissolved oxygen (DO) meter, with replaceable polytetrafluoroethylene (PTFE) membrane caps and protective shield, designed to provide reliable measurements under harsh environmental conditions. The HI9142 is supplied complete with polarographic probe, PTFE membrane caps, electrolyte fill solution, protective shield, and rugged carrying case.
Features:
- Replaceable, pretensioned, polytetrafluoroethylene (PTFE) membranes with a screw cap design for simple filling of electrolyte and easy replacement.
- Polarographic measuring system based on the Ross and Clark polarographic measurement method
- The probe uses a platinum cathode and silver anode in an electrolyte solution using external voltage to establish a current proportional to the concentration of dissolved oxygen
- Manual one or two point calibration at 100% and automatic calibration in zero oxygen solution
- A high-accuracy, built-in linearized thermistor temperature sensor behind a stainless steel cover
- All readings are automatically compensated for temperature variations

Specifications

- Dissolved Oxygen Measurement Type: polarographic
- Dissolved Oxygen Range: 0.0 to 19.9 mg/L (ppm)
- Dissolved Oxygen Resolution: 0.1 mg/L (ppm)
- Dissolved Oxygen Accuracy: +/- 1.5% F.S.
- Dissolved Oxygen: Calibration manual in 100%; automatic in 0% DO
- Dissolved Oxygen: Temperature Compensation automatic, 0 to 50 C (32 to 122 F)
- Temperature Range: -5.0 to 50.0 C (23.0 to 122.0 F)
- Temperature Resolution: 0.1 C (1 F)
- Temperature Accuracy: +/- 0.2 C (+/- 1 F) (excluding probe error)
- DO Probe: HI 76407 with 4 m (13') cable (included)
- Automatic Shut-Off: After approx. 8 minutes
- Battery Type/Life: 1.5V AA (4) / approx. 500 hours of use
- Environment: 0 to 50 C (32 to 122 F); RH max 100%
- Dimensions: 196 x 80 x 60 mm (7.7 x 3.1 x 2.4 inches)
- Weight: 500 g (1.1 lb.)
Ordering Information:
The HI9142 is supplied complete with HI76407 DO probe, HI76407A/P pre-formed PTFE DO membranes (2), HI7041S electrolyte solution (30 mL), batteries, instructions and rugged carrying case.

Our Reviews



Recently Viewed

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au