Ensure safety and effectiveness during agricultural spraying with the Kestrel 3500 Delta T.

To ensure safety and effectiveness when spraying, it is critical to measure relative humidity, wind speed and wind direction. Many locales regulate the maximum permitted wind speed during spraying to minimize spray drift. In hot, dry conditions, expensive chemicals may evaporate into the air rather than onto your crops. However, you can minimize costly evaporation by selecting an appropriate nozzle and increasing the spray droplet size..

Quickly & Accurately Calculates Delta T For You

The Kestrel 3500 DT incorporates a Delta T calculation, the spread between the wet bulb temperature and the dry bulb temperature (indegrees C). Delta T offers a quick guide to determining acceptable spraying conditions. For example, it is not recommended to apply pesticides when Delta T is above 10 a range of 2 to 8 is ideal. With the Kestrel 3500 Delta T, the calculation is done for you accurately and simply.

The Kestrel 3500 Delta T incorporates barometric pressure correction units wet bulb temperature calculation, ensuring accuracy even on low pressure days, at high altitudes, and in very dry weather when Delta T monitoring is important. No other pocket weather meter offers this feature with this level of accuracy.

What does the Kestrel 3500 measure?
- Delta T
- Wind speed (current, average, and maximum)
- Temperature of air, water & snow in F or C
- Relative humidity in %
- Dewpoint
- Barometric pressure
- Altitude
- Wet bulb temperature

Features
- Real-time clock
- Protective cover with sure-grip overmolding
- Data hold function
- Large easy-to-read display with backlight
- Waterproof and floats
- Measure environmental conditions quickly and accurately
- Forecast weather with pressure trend indicator
- Reliable, portable and easy to use
- Innovative humidity sensor designed for stability and accuracy in abrupt condition changes
- Thermally adjusted humidity sensor
- Patented user-replaceable impeller
- Quick response, external thermistor
- High precision pressure sensor
- Humidity sensor can be recalibrated in the field with our Relative Humidity Calibration Kit.
- All instruments and accessories are completely assembled in the USA
- 5 year warranty

Specifications


Kestrel 3500 Includes
- A slip-on protective cover
- Neck lanyard
- CR2032 coin cell battery (Average life 300 hours)
- Kestrel Certificate of Conformity

Measurement
Response Time
Units Operational Range Resolution Accuracy (+/-)

Specifications

Range
Wind Speed
1 second
m/s 0.4 to 60.0 m/s 0.1 0.4 to 40.0 m/s
ft/min 59 to 11,948 ft/min 1 59 to 7877 ft/min
km/h 1.0 to 218.0 km/h 0.1 Larger of 3% of reading or least significant digit 1.0 to 144.0 km/h
mph 0.8 to 135.0 mph 1 0.8 to 89.0 mph
knots 0.6 to 118.3 kt 0.1 0.6 to 78.0 k
Beaufort 0 to 12 B 0.1 0 to 12 B
1 inch diameter impeller with precision axle and sapphire bearings. Calibration drift < 1% after 100 hours use at 16 MPH / 7 m/s. Sustained operation above 60 MPH / 27 m/s will wear impeller rapidly and may cause destruction of impeller. Replacement impeller (NK PN-0801) maybe field-installed without tools (US Patent 5,783,753).
Temperature
1 second
F -49.0 to 257.0 F 0.1 -20.0 to 158.0 F
C -45.0 to 125.0 C 0.1 -29.0 to 70.0 C
Measures air, water and snow temperature. Thermally isolated, hermetically sealed, precision thermistor mounted externally (US Patent 5,939,645). Calibration drift negligible.
Relative Humidity
1 minute
%RH 0.0 to 100.0 % 0.1 3.0 %RH 5.0 to 95.0 % non-condensing
Polymer capacitive humidity sensor mounted in thin-walled chamber external to case for rapid, accurate response (US Patent 6,257,074). (To achieve stated relative humidity accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and must be kept out of direct sunlight.) Calibration drift +/- 2% over 24 months. Relative humidity may be recalibrated at factory or in field using Kestrel Humidity Calibration Kit (NK PN-0802).
Pressure
1 second
(mb & PSI 4000 model only)
inHg 0.3 to 32.5 inHg 0.01 0.05 inHg At 77.0 F, 22.1 to 32.5 inHg
hPa / mb 10.0 to 1100.0 hPa / mb 0.1 1.5 hPa / mb At 25.0 C, 750 to 1100 hPa / mb
PSI 0.15 to 16.0 PSI 0.01 0.02 PSI At 77.0 F, 10.9 to 16.0 PSI
Monolithic silicon piezoresistive pressure sensor with second-order temperature correction. Maximum error over temperature range 32 to 158 F (0 to 70 C) , +/- 0.06 inHg / +/-2.0 hPa. Calibration drift typically -0.03 inHg / -1.0 hPa per year. Pressure sensor may be recalibrated at factory or in field.
Altitude
1 second
ft -6000 to 30000 ft 1 50 ft At 77.0 F, <19,700 ft. Max error +/- 98 ft
m -2000 to 9000 m 1 15 m At 25.0 C, <6,000 m. Max error +/- 30 m
Temperature compensated pressure (barometric) altimeter.
Dewpoint
1 minute
F 0.0 to 100.0 %RH, -49.0 to 257.0 F 0.1 3.6 F -20.0 to 158.0 F, 20.0 to 95.0% RH
C 0.0 to 100.0 %RH, -45.0 to 125.0 C 0.1 2.0 C -29.0 to 70.0 C, 20.0 to 95.0 %RH
Calculated from the primary measurements of temperature and relative humidity. Temperature to which the air would need to be cooled at a constant pressure to become saturated.
Wet Bulb Temperature 1 minute F -49.0 to 257.0 F, 0.0 to 100.0 %RH, 8.86 to 32.48 inHg 0.1 3.6 F 32.0 to 100.0 F, 5.0 to 95.0% RH, 8.86 to 32.48 inHg, <19700 ft
C -45.0 to 125.0 C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hPa 0.1 2.0 C 0.0 to 37.8 C, 5.0 to 95.0 %RH, -2000.0 to 9000.0 hPa, <6000 m
Calculated from the primary measurements of temperature, relative humidity and pressure. Temperature indicated by a wet bulb psychrometer.
Max/Avg Wind Speed One-button clear and restart of Max Wind Gust and Average Wind measurement.
Pressure Trend Continuously updating three-hour barometric pressure trend indicator: rising rapidly, rising, steady, falling, falling rapidly.
Display Reflective 4 digit LCD. Digit height 0.36 in / 9 mm.
Display Update 1 second.
Display Backlight Aviation green electroluminescent backlight.
Clock / Calendar Real-time hours:minutes clock.
Operational Temperature Range
(LCD and Batteries)
The operational temperature range of the liquid crystal display and batteries is 14 F to 131 F / -10 C to 55 C. Beyond the limits of the operational temperature range, the unit must be maintained within range and exposed for minimum time necessary to take reading.
Storage Temperature -22 F to 140 F / -30 C to 60 C.
Auto Shutdown After 45 minutes of no key presses.
Certifications CE certified. Individually tested to NIST-traceable standards (written certificate of tests available at additional charge).
Batteries CR2032, one, included. Average life, 300 hours of use, +/-depending on backlight use.
Environmental Waterproof (IP67 standard). Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage replaceable impeller.).
Dimensions Unit 4.8 x 1.7 x 0.7 in / 122 x 42 x 18 mm. Case 4.8 x 1.9 x 1.1 in / 122 x 48 x 28 mm.
Weight Unit 2.3 oz / 65 g. Case 1.3 oz / 37 g.

Our Reviews



Recently Viewed

Instrument Choice will respond in 3 business hours

Get in touch with our expert scientists Instrument Choice.

In less than 3 business hours you will have an answer from our expert scientists.

Our Australian experts have access to a huge range of products from national and international suppliers.

If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au