INDUSTRIAL TRUE RMS MULTIMETER - IC-FLUKE-87-5
Backorder Now, once ordered your item will dispatch before the 17th of May 2025, call 1300 737 871 (NZ 0800 737 871 to confirm).
$1,388.20 AUD Inc. GST




Features:
• True-rms ac voltage and current for accurate measurements on non linear signals
• Selectable filter for accurate voltage and frequency measurements on motor drives
• 0.05 % dc accuracy
• 4-1/2 digit mode for precise measurements (20,000 counts)
• Built in thermometer lets you carry one less tool (TC probe included)
• 6000 counts, 3-3/4 digits
• Measure up to 1000 V ac and dc
• Measure up to 10 A, 20 A for up to 30 seconds
• Frequency to 200 kHz and % duty cycle
• Resistance, continuity and diode test
• 10,000 µF capacitance range for components and motor caps
• Min/Max-Average recording with Min/Max Alert to capture variations automatically
• Peak capture to record transients as fast as 250 µs
• Relative mode to remove test lead interference from low ohms measurements
• Auto and manual ranging for maximum flexibility
• Touch Hold to capture stable readings avoiding noisy signals
• Large display digits and two-level bright white backlight for increased visibility
• Analog bargraph for fast changing or unstable signals
• Input Alert provides audible warning against wrong use of input jacks
• Improved selectable sleep mode for long battery life
• Access door for fast battery changes without breaking the calibration seal
• "Classic" design with new removable holster with built in test lead and probe storage
• Lifetime warranty
Specifications
Voltage (DC) maximum voltage: 1000V
Voltage (DC) accuracy: ±(0.05%+1)
Voltage (DC) maximum resolution: 10 µV
Voltage (AC) maximum voltage: 1000V
Voltage (AC) Accuracy: ±(0.7%+2) True RMS
Voltage (AC) Bandwidth: 20kHz
Current (DC) maximum Amps: 10A (20 A for 30 seconds maximum)
Current (DC) Amps Accuracy: ±(0.2%+2)
Current (DC) maximum resolution: 0.01 mA
Current (AC) maximum Amps: 10A (20 A for 30 seconds maximum)
Current (AC) Amps accuracy: ±(1.0%+2)
Current (AC) maximum resolution: 0.1 µA
Resistance: 50 MO
Resistance accuracy and resolution: ±(0.4%+1). 0.1O
Maximum Capacitance" 9,999 µ
Capacitance accuracy and resolution: ±(1%+2), 0.1O
Maximum Frequency: 200 kHz
Frequency accuracy: ±(0.005%+1)
Maximum Resolution: 0.01 Hz
Temperature Measurement: -200.0°C - 1090°C (-328.0°F - 1994.0°F)
Maximum conductance: 60.00 nS
Conductance accuracy and resolution: ±(1.0%+10), 0.1%
Our Reviews
Recently Viewed
Instrument Choice will respond in 3 business hours
Get in touch with our expert scientists Instrument Choice.
In less than 3 business hours you will have an answer from our expert scientists.
Our Australian experts have access to a huge range of products from national and international suppliers.
If for any reason you have trouble using this form please email the following address and your enquiry will still receive a response from a scientist within 3 business hours: scientists@instrumentchoice.com.au